JIABO · Self-priming oil pump manufacturer in China

Self-priming electric oil-transfer pumps for industrial transfer duties.

JIABO supplies self-priming oil-transfer pumps for diesel, lubricating oil and compatible petroleum-liquid duties after application review. Select the exact pump by oil grade, viscosity at operating temperature, required flow, discharge pressure, suction lift, seal materials, motor supply and hazardous-area requirements.

JIABO self-priming oil pump

Choose a series

Oil pumps range.

The supplied factory photos show several oil-pump configurations but do not identify exact models or certified performance ratings. Request a current datasheet before choosing a pump.

Catalog-backed model data

Click a range to compare models.

Values are transcribed from the supplied manufacturer catalogs. Confirm the current curve, materials, and operating limits before ordering.

KCB and 2CY gear-oil pump parameters and dimensions

Complete supplied KCB/2CY table. Flow, pressure and vacuum are performance references; H, L, L1, L2, L3, A, B, C, D and K are dimensions in millimetres unless the entry is a threaded connection.

ModelFlow (m³/h)Pressure (MPa)Vacuum (m H₂O)Inlet / outletHLL1L2L3ABCDn–mPort distance KMotor modelPower (kW)
KCB18.3 / 2CY1.1/14.51.11.455G3/4"1095834057225020525079——200Y90L-41.5
KCB33.3 / 2CY2/14.521.455G3/4"1196184377225020525079——200Y100L1-42.2
KCB55 / 2CY3.3/3.33.30.335G1"1095884057225020525086——200Y90L-41.5
KCB83.3 / 2CY5/3.350.335G1 1/2"1196584377225020525099——200Y100L2-42.2
KCB133 / 2CY8/3.380.335G2"18277868813045025034032——260Y132S-63
2CY8/680.65G2"18281868813045025034032——260Y132M1-64
2CY8/1081.05G2"18281868813045025034032——260Y132M2-65.5
2CY12/1.3120.135G2"17270357613037025030532——260Y112M-44
KCB200 / 2CY12/3.3120.335G2"18277868813045025034032——260Y132S-45.5
2CY12/6120.65G2"18277868813045025034032——260Y132S-45.5
2CY12/10121.05G2"18281868813045025034032——260Y132M-47.5
KCB300 / 2CY18/3.6180.36570187898723120480280340451236-M14234Y132M2-65.5
2CY18/6180.6570242983912155600280380301236-M14234Y160M-67.5
KCB483 / 2CY29/3.6290.36570187898723120480280340451236-M14234Y132M-47.5
2CY29/6290.6570242983912155600280380301236-M14234Y160M-411
KCB633 / 2CY38/2.8380.2851002301094912155600280380601588-M16280Y160L-611
2CY38/6380.651002861224943150650360360651588-M16280Y200L2-622
KCB960 / 2CY60/3600.351002301159955155650280410601588-M16280Y180L-422
2CY100/31000.3515044015861325110550×2450450-202108-M16400Y250M-830
2CY100/61000.6515046518561536138420×360060082108-M16400Y315S-855
2CY120/31200.3515044015861325110550×2450450-202108-M16400Y250M-830
2CY120/61200.6515046518561536138420×360060082108-M16400Y315S-855
2CY150/31500.3515046016961376138550×250050082108-M16400Y280S-837
2CY150/61500.6515046519461536138420×360060082108-M16400Y315M1-875

Range comparison

Which arrangement should you investigate?

These distinctions help narrow the inquiry. They are not a substitute for an exact model curve or materials list.

Series / arrangementWhat distinguishes itConfirm before selection
Self-priming oil pumpThe pictured series is presented for oil-transfer inquiries where self-priming capability may be needed.Oil grade, viscosity at operating temperature, suction lift and seal compatibility.
Other transfer dutiesDo not assume one pump is suitable for every fuel, lubricant or chemical mixture.Fluid safety data, temperature, hazardous-area requirements and exact model approval.

Supplied product photos

See the equipment.

Photos show configurations within this range. They do not establish a model’s flow, head, pressure or materials; check the current datasheet before ordering.

Typical applications

Where it may fit.

  • Oil-transfer inquiries
  • Project-specific fluid handling
  • Systems requiring a self-priming arrangement, subject to model confirmation

For a model recommendation

What to send us.

  • Oil grade and viscosity at working temperature
  • Required flow, pressure and suction conditions
  • Seal and wetted-material requirements
  • Electrical supply and connection arrangement

Popular buyer searches

Find the right oil pumps by application.

These search terms are useful starting points. Final selection still requires the exact liquid, duty point and installation conditions.

Self-priming oil transfer pump

Specify oil grade, viscosity at working temperature, flow, discharge pressure and actual suction lift; self-priming does not mean unlimited suction capability.

Electric diesel transfer pump

Diesel service requires confirmation of seal materials, motor and hazardous-area requirements, duty cycle and local electrical standard.

Lubricating oil pump

Viscosity strongly affects capacity and motor loading, so send the lubricant grade and minimum and maximum operating temperature.

Buyer questions

Oil pumps: practical answers.

For final selection, confirm the exact model and operating conditions with JIABO.

How do I choose a self-priming oil transfer pump?

Provide the oil or fuel name, viscosity and temperature, required flow and discharge pressure, suction lift, pipe sizes, duty cycle, power supply and any hazardous-area classification. The exact seal, motor and wetted materials must match the liquid and site.

Can the same electric oil-transfer pump handle diesel and lubricating oil?

Not automatically. Diesel and lubricating oils can have very different viscosity, vapor, temperature and seal requirements. Confirm the exact liquid and operating temperature against the model data before ordering.

Is the pictured self-priming pump suitable for every oil?

No. Confirm oil grade, viscosity at operating temperature, seal and wetted materials, and any hazardous-area requirements for the exact model.

Does self-priming mean unlimited suction lift?

No. Suction lift depends on the exact pump, liquid, temperature and pipe losses. Share the source level, suction pipe details and installation elevation for a model check.

What information is needed for an oil-pump quote?

Provide the oil grade and safety information, viscosity and temperature, required flow and pressure, suction conditions, power supply and connection size.

Before choosing a model

Prepare the duty point and liquid details.

Our selection guides show what to measure and what to ask for in the current technical sheet.

Read selection guides →

Talk to JIABO

Ask for the current model table and quotation.

Share the liquid, required duty point, power supply and installation details.

Send an inquiry

Leave your pump requirements.

Include the model if known. For selection help, add the liquid, required flow, head or pressure, power supply, and installation conditions.

Email: sales@jiabofluid.comTel: +86 571 2328 1234Solar pump WhatsApp: +86 133 4581 6945Other pumps WhatsApp: +86 137 6186 8190
No. 788, Jintang Road, Jiangnan Town, Tonglu County, Hangzhou City, Zhejiang Province, China

Your inquiry is sent directly to JIABO sales. Form details are processed by our delivery service to email them to us.