Self-priming oil transfer pump
Specify oil grade, viscosity at working temperature, flow, discharge pressure and actual suction lift; self-priming does not mean unlimited suction capability.
Ask about this rangeJIABO · Self-priming oil pump manufacturer in China
JIABO supplies self-priming oil-transfer pumps for diesel, lubricating oil and compatible petroleum-liquid duties after application review. Select the exact pump by oil grade, viscosity at operating temperature, required flow, discharge pressure, suction lift, seal materials, motor supply and hazardous-area requirements.

Choose a series
The supplied factory photos show several oil-pump configurations but do not identify exact models or certified performance ratings. Request a current datasheet before choosing a pump.
Catalog-backed model data
Values are transcribed from the supplied manufacturer catalogs. Confirm the current curve, materials, and operating limits before ordering.
Complete supplied KCB/2CY table. Flow, pressure and vacuum are performance references; H, L, L1, L2, L3, A, B, C, D and K are dimensions in millimetres unless the entry is a threaded connection.
| Model | Flow (m³/h) | Pressure (MPa) | Vacuum (m H₂O) | Inlet / outlet | H | L | L1 | L2 | L3 | A | B | C | D | n–m | Port distance K | Motor model | Power (kW) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| KCB18.3 / 2CY1.1/14.5 | 1.1 | 1.45 | 5 | G3/4" | 109 | 583 | 405 | 72 | 250 | 205 | 250 | 79 | — | — | 200 | Y90L-4 | 1.5 |
| KCB33.3 / 2CY2/14.5 | 2 | 1.45 | 5 | G3/4" | 119 | 618 | 437 | 72 | 250 | 205 | 250 | 79 | — | — | 200 | Y100L1-4 | 2.2 |
| KCB55 / 2CY3.3/3.3 | 3.3 | 0.33 | 5 | G1" | 109 | 588 | 405 | 72 | 250 | 205 | 250 | 86 | — | — | 200 | Y90L-4 | 1.5 |
| KCB83.3 / 2CY5/3.3 | 5 | 0.33 | 5 | G1 1/2" | 119 | 658 | 437 | 72 | 250 | 205 | 250 | 99 | — | — | 200 | Y100L2-4 | 2.2 |
| KCB133 / 2CY8/3.3 | 8 | 0.33 | 5 | G2" | 182 | 778 | 688 | 130 | 450 | 250 | 340 | 32 | — | — | 260 | Y132S-6 | 3 |
| 2CY8/6 | 8 | 0.6 | 5 | G2" | 182 | 818 | 688 | 130 | 450 | 250 | 340 | 32 | — | — | 260 | Y132M1-6 | 4 |
| 2CY8/10 | 8 | 1.0 | 5 | G2" | 182 | 818 | 688 | 130 | 450 | 250 | 340 | 32 | — | — | 260 | Y132M2-6 | 5.5 |
| 2CY12/1.3 | 12 | 0.13 | 5 | G2" | 172 | 703 | 576 | 130 | 370 | 250 | 305 | 32 | — | — | 260 | Y112M-4 | 4 |
| KCB200 / 2CY12/3.3 | 12 | 0.33 | 5 | G2" | 182 | 778 | 688 | 130 | 450 | 250 | 340 | 32 | — | — | 260 | Y132S-4 | 5.5 |
| 2CY12/6 | 12 | 0.6 | 5 | G2" | 182 | 778 | 688 | 130 | 450 | 250 | 340 | 32 | — | — | 260 | Y132S-4 | 5.5 |
| 2CY12/10 | 12 | 1.0 | 5 | G2" | 182 | 818 | 688 | 130 | 450 | 250 | 340 | 32 | — | — | 260 | Y132M-4 | 7.5 |
| KCB300 / 2CY18/3.6 | 18 | 0.36 | 5 | 70 | 187 | 898 | 723 | 120 | 480 | 280 | 340 | 45 | 123 | 6-M14 | 234 | Y132M2-6 | 5.5 |
| 2CY18/6 | 18 | 0.6 | 5 | 70 | 242 | 983 | 912 | 155 | 600 | 280 | 380 | 30 | 123 | 6-M14 | 234 | Y160M-6 | 7.5 |
| KCB483 / 2CY29/3.6 | 29 | 0.36 | 5 | 70 | 187 | 898 | 723 | 120 | 480 | 280 | 340 | 45 | 123 | 6-M14 | 234 | Y132M-4 | 7.5 |
| 2CY29/6 | 29 | 0.6 | 5 | 70 | 242 | 983 | 912 | 155 | 600 | 280 | 380 | 30 | 123 | 6-M14 | 234 | Y160M-4 | 11 |
| KCB633 / 2CY38/2.8 | 38 | 0.28 | 5 | 100 | 230 | 1094 | 912 | 155 | 600 | 280 | 380 | 60 | 158 | 8-M16 | 280 | Y160L-6 | 11 |
| 2CY38/6 | 38 | 0.6 | 5 | 100 | 286 | 1224 | 943 | 150 | 650 | 360 | 360 | 65 | 158 | 8-M16 | 280 | Y200L2-6 | 22 |
| KCB960 / 2CY60/3 | 60 | 0.3 | 5 | 100 | 230 | 1159 | 955 | 155 | 650 | 280 | 410 | 60 | 158 | 8-M16 | 280 | Y180L-4 | 22 |
| 2CY100/3 | 100 | 0.3 | 5 | 150 | 440 | 1586 | 1325 | 110 | 550×2 | 450 | 450 | -20 | 210 | 8-M16 | 400 | Y250M-8 | 30 |
| 2CY100/6 | 100 | 0.6 | 5 | 150 | 465 | 1856 | 1536 | 138 | 420×3 | 600 | 600 | 8 | 210 | 8-M16 | 400 | Y315S-8 | 55 |
| 2CY120/3 | 120 | 0.3 | 5 | 150 | 440 | 1586 | 1325 | 110 | 550×2 | 450 | 450 | -20 | 210 | 8-M16 | 400 | Y250M-8 | 30 |
| 2CY120/6 | 120 | 0.6 | 5 | 150 | 465 | 1856 | 1536 | 138 | 420×3 | 600 | 600 | 8 | 210 | 8-M16 | 400 | Y315S-8 | 55 |
| 2CY150/3 | 150 | 0.3 | 5 | 150 | 460 | 1696 | 1376 | 138 | 550×2 | 500 | 500 | 8 | 210 | 8-M16 | 400 | Y280S-8 | 37 |
| 2CY150/6 | 150 | 0.6 | 5 | 150 | 465 | 1946 | 1536 | 138 | 420×3 | 600 | 600 | 8 | 210 | 8-M16 | 400 | Y315M1-8 | 75 |
Range comparison
These distinctions help narrow the inquiry. They are not a substitute for an exact model curve or materials list.
| Series / arrangement | What distinguishes it | Confirm before selection |
|---|---|---|
| Self-priming oil pump | The pictured series is presented for oil-transfer inquiries where self-priming capability may be needed. | Oil grade, viscosity at operating temperature, suction lift and seal compatibility. |
| Other transfer duties | Do not assume one pump is suitable for every fuel, lubricant or chemical mixture. | Fluid safety data, temperature, hazardous-area requirements and exact model approval. |
Supplied product photos
Photos show configurations within this range. They do not establish a model’s flow, head, pressure or materials; check the current datasheet before ordering.






Typical applications
For a model recommendation
Popular buyer searches
These search terms are useful starting points. Final selection still requires the exact liquid, duty point and installation conditions.
Specify oil grade, viscosity at working temperature, flow, discharge pressure and actual suction lift; self-priming does not mean unlimited suction capability.
Diesel service requires confirmation of seal materials, motor and hazardous-area requirements, duty cycle and local electrical standard.
Viscosity strongly affects capacity and motor loading, so send the lubricant grade and minimum and maximum operating temperature.
Buyer questions
For final selection, confirm the exact model and operating conditions with JIABO.
Provide the oil or fuel name, viscosity and temperature, required flow and discharge pressure, suction lift, pipe sizes, duty cycle, power supply and any hazardous-area classification. The exact seal, motor and wetted materials must match the liquid and site.
Not automatically. Diesel and lubricating oils can have very different viscosity, vapor, temperature and seal requirements. Confirm the exact liquid and operating temperature against the model data before ordering.
No. Confirm oil grade, viscosity at operating temperature, seal and wetted materials, and any hazardous-area requirements for the exact model.
No. Suction lift depends on the exact pump, liquid, temperature and pipe losses. Share the source level, suction pipe details and installation elevation for a model check.
Provide the oil grade and safety information, viscosity and temperature, required flow and pressure, suction conditions, power supply and connection size.
Before choosing a model
Our selection guides show what to measure and what to ask for in the current technical sheet.
Talk to JIABO
Ask for the current model table and quotation.Share the liquid, required duty point, power supply and installation details.
Send an inquiry
Include the model if known. For selection help, add the liquid, required flow, head or pressure, power supply, and installation conditions.